RFL SMX3/40 Page 9 of 24 Issue 2.02
User Manual
07 May 2009
Optional Concatenation Port Pin-out (when in DCE configuration) – D15F
Circuit Pin A Pin B Direction Notes
T Transmit Data 2 9 Input
R Receive Data 4 11 Output
C Control 3 10 Input Signal ignored
I Indication 5 12 Output Permanently on
S Signal Element
Timing
6 13 Output Timing signal transmitted
to network
G Ground 8 15
Screen / Drain
Must be earthed to shell
Aggregate Concatenation
Aggregate Concatenation is the interconnection at aggregate level of two co-located
SMX3/40 units. In this mode the Concatenation Port is enabled as DTE with Timing X
enabled. The timing signal is then transmitted on pins 7 and 14 (Xa and Xb).
Aggregate Concatenation to a co-located SMX3/40 requires a five twisted pair cross-
over cable of, pins A to A and B to B:
Aggregate Concatenation Cable
D15M – D15M
Pair Pin End A End B
A 2 4
1
B 9 11
A 4 2
2
B 11 9
A 6 7
3
B 13 14
A 7 6
4
B 14 13
A 8 8
5
B 15 15
Screen / Drain
Must be earthed to
connector shells at
both ends
Use 5 pair plus ground stranded cable with overall shield (eg RS 111-8988).
Maximum recommended length 5m; absolute maximum 10m.
DIP switches provide configuration options, see section 10.